The cold snap playbook: your heat pump in an arctic blast

During a rare South Sound arctic event, your heat pump's job is to run steadily — and yours is mostly to leave it alone. Pick a comfortable setpoint and hold it, expect longer run times and occasional steam from the outdoor unit (that's defrost working, not a fire), let backup heat stage in if the system calls for it, and never chip ice off the outdoor coil.

WA Lic. INFINHA841B8 400+ Google reviews

Quick answer

  • Steam rising off the outdoor unit every hour or two is the defrost cycle doing its job — normal, not a malfunction.
  • Never chip, pry, or pour hot water on ice on the outdoor coil; the fins and refrigerant tubing damage easily.
  • Set a comfortable temperature and hold it — don't crank the thermostat up, which just forces expensive backup heat on.
  • Longer, near-continuous run times in deep cold are expected behavior for an inverter heat pump, not a sign of struggle.
Call or schedule service

What normal looks like in deep cold

In a hard freeze a heat pump behaves differently than it does at 45°F, and most of the differences are by design. It runs much longer cycles — possibly close to continuously — because it's sized for our normal climate, not the rare extreme. Supply air feels warm rather than hot, since heat pumps deliver lower supply temperatures than a furnace. Frost forms on the outdoor coil, and every so often the unit pauses heating, may hiss or whoosh, and sends up a plume of steam as it melts that frost off. All of this is normal. What's not normal: no heat at all, ice encasing the whole unit for hours, or grinding sounds from the fan.

The ice rules

A frost coating that comes and goes with defrost cycles needs nothing from you. Solid ice that keeps building is worth a service call — but never take matters into your own hands with an ice scraper, screwdriver, or kettle of hot water. The aluminum fins bend with almost no force, the refrigerant tubing behind them punctures, and hot water refreezes into a worse problem. What you can safely do: brush snow off the top of the unit with a broom, keep the area around it clear so defrost meltwater drains away, and check that snow hasn't drifted against the coil. If the unit sits under a roof edge, watch for dripping that refreezes onto it.

Backup heat: what it is and when to let it work

Most ducted heat pumps here carry backup heat — electric heat strips, or a gas furnace in a dual-fuel setup. The system stages it in automatically when the heat pump alone can't hold setpoint, and during a genuine arctic blast, that's exactly what it's for. You may see a thermostat indicator like 'aux heat' — that's information, not an alarm. Electric backup costs more to run than the heat pump, which is one more reason not to crank the setpoint: a big jump tells many thermostats to skip straight to backup. If your system has no backup and can't hold temperature in an extreme event, space-heat one room, close doors, and call us.

Thermostat habits for the duration

Set it and leave it. Pick a livable temperature and hold it day and night until the cold passes — this is the one week of the year when overnight setbacks genuinely backfire, because recovering from a setback in extreme cold leans hard on backup heat. Avoid 'emergency heat' mode unless the heat pump has actually failed; it's a manual override that runs backup only, at backup prices. Help the system out around the edges: keep interior doors open so air circulates, close curtains at night, and let warm-side rooms share with cold-side rooms. The house may sit a degree or two below setpoint at the coldest hour — that's a sized-for-our-climate system meeting a not-our-climate day, and it recovers.

When to actually call

No heat with the system running, the whole outdoor unit encased in ice that defrost never clears, breakers tripping repeatedly, or grinding and scraping from the outdoor fan. And if the home has infants, elders, or medical equipment and is losing temperature, call the 24/7 line — that's what it exists for.

Ready for the next step?

Talk it through with the family-run team that answers 24/7 — honest advice first, quotes only after we've actually seen your home.

Family owned · WA Lic. INFINHA841B8 · 400+ Google reviews

Common questions

The outdoor unit is steaming — is something burning?

No. During defrost the system briefly reverses to warm the outdoor coil, and the melting frost flashes into vapor. A steam plume every hour or two in cold weather is the sign of a healthy defrost cycle.

Should I switch to emergency heat when it gets really cold?

No — emergency heat is for when the heat pump itself has failed. Cold-climate heat pumps keep producing heat far below normal Northwest temperatures, and the system stages backup heat automatically when it's genuinely needed.

My heat pump runs constantly in a cold snap. Is it wearing itself out?

Long, steady runs are how inverter heat pumps are designed to work — gentle continuous output is easier on components than frequent starts and stops. If it runs constantly and the house is still losing temperature, that's worth a call.

Ready to act on this?

Maintenance plans & tune-ups

Continue exploring

Infinity Heating & Air — licensed WA HVAC contractor (Lic. INFINHA841B8), family-owned in Graham. Last updated July 2026.

Choose Infinity & enjoy endless comfort.

Your perfect home environment awaits — call (253) 740-5135 or schedule service online and our team will take it from there.

Open 24/7 · 100% Satisfaction Guaranteed · Graham, WA

Before you go — got a quote from someone else?

Bring us any repair or replacement quote and our licensed family team will verify it — free, honest, no pressure. If their price and diagnosis are right, we'll tell you.

Family owned · WA Lic. INFINHA841B8 · 400+ Google reviews